CP 6000VA/W Rack Tower UPS

CP 6000VA/W Rack Tower UPS

SKU: OL6KERTHD

Cables and Electrical UPS / Rack Systems

$8899.00 AUD inc. GST
Out of Stock — available to order
Brand CyberPower
Weight 0.05 kg

Product Description

CyberPower OL6KERTHD guarantees power backup protection for IT equipment, servers, workstations, NAS/Storage devices, telecom devices, networking devices, security/emergency and surveillance systems. The UPS adopts double-conversion topology. Specifications: Phase: Single Phase Form Factor: Rackmount, Tower UPS Topology: Online Double Conversion Energy Saving Technology: Online ECO Mode Efficiency > 97% Active PFC Compatibility: Yes Generator Compatibility: Yes Nominal Input Voltage ( Vac ): 200 ± 2% | 208 ± 2% | 220 ± 2% | 230 ± 2% | 240 ± 2% Input Voltage Range ( Vac ): 200 - 240 Adjustable Voltage Range ( Vac ): 0-25% Load for 120 - 139 Vac | 0-50% Load for 140 - 159 Vac | 0-75% Load for 160 - 179 Vac | 0-100% Load for 180 - 280 Vac Input Frequency ( Hz ): 50 ± 10 | 60 ± 10 Input Frequency Detection: Auto-sensing Rated Input Current ( A ): 32 Input Power Factor: 0.99 Input Connector Type: Hardwire Terminal Block Output Capacity (Watts): 6000 On Battery Waveform: Pure Sine Wave On Battery Voltage(s) ( Vac ): 200 ± 2% | 208 ± 2% | 220 ± 2% | 230 ± 2% | 240 ± 2% Output Voltage Setting: Configurable On Battery Frequency ( Hz ): 50 ± 0.5% | 60 ± 0.5% Output Frequency Setting: Configurable Power Factor: 1 ECO Mode Voltage Tolerance: ± 10 % | ± 15 % Overload Protection: Internal Current Limiting, Circuit Breaker Overload Protection (Line Mode): 105-125% Load for 1 min, 125-150% Load for 10 sec Overload Protection (Battery Mode): 105-130% Load for 10 sec, 130-150% Load for 2 sec Overload Protection (Bypass Mode): Circuit Breaker Crest Factor: 3 : 1 Harmonic Distortion (Linear Load): THD 3% Harmonic Distortion (Non-linear Load): THD 5% Internal Bypass: Automatic Bypass, Manual Bypass Outlet(s) - Total: 7 Outlet Type: IEC C13 x 4 | IEC C19 x 2 | Hardwire Terminal Block x 1 Outlet(s) - Battery & Surge Protected: 7 Outlet(s) - Critical Load (CL): 4 Outlet(s) - Non-Critical Load (NCL): 3 Typical Transfer Time ( ms ): 0 Runtime at Half Load ( min ): 4.9 Runtime at Full Load ( min ): 1.4 Typical Recharge Time ( Hours ): 4 Start On Battery: Yes Smart Battery Management (SBM): Yes Built-in Battery Management Module: Yes User-replaceable: Yes - Qualified Personnel Only Hot-swappable: Yes Battery Type: Sealed Lead-acid Replacement Battery Pack: RBP0144 RBP Quantity ( pcs ): 1 Battery Quantity (Each RBP) ( pcs ): 12 Battery Voltage (Each RBP) ( V ): 144 Compatible Extended Battery Module (EBM): BPE144VL2U01 (Built-in Charger) Max. EBM Quantity ( pcs ): 10 Surge Suppression ( Joules ): 2430 EMI/RFI Filtration: Yes LCD Orientation: Rotatable LCD - Automatic, Rotatable LCD via Setting Tiltable LCD Panel: 18° LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log LCD Setting & Control: Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting, Language HID Compliant USB Port(s): 1 Emergency Power Off (EPO) Port: Yes Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery Management Cable ( pcs ): USB Cable x1, Serial Cable x1 Power Management Software: PowerPanel Business (Recommended) SNMP/HTTP Remote Monitoring: Yes - RMCARD205 included Enclosure Construction: Metal Rackmount Rail: Yes Rackmount Ears: Yes Dimensions: 433 x 86.5 x 720mm Rack-mounted Dimensions: 433 x 86.5 x 685mm (Without the dimension of front panel) Weight: 42kg Certifications: CE, EAC, RCM Features: Online (Double Conversion) UPS Topology High Density Design High Output Power Factor Tiltable LCD Panel Surge and Spike Protection Generator Compatible Hot-swappable Batteries Smart Battery Management (SBM) SNMP/HTTP Remote Management Capability ECO Mode Color LCD Panel Quick Charging Technology Automatically rotatable LCD Critical/Non-critical Load Outlets Battery Management Technology Extended Battery Module (EBM) Emergency Power Off (EPO) Port PowerPanel Management Software