CP 40KVA/40KW Rack UPS

CP 40KVA/40KW Rack UPS

SKU: OL3T040KERTHD

Power UPS

$6369.00 AUD inc. GST
Out of Stock — available to order
Brand CyberPower
Weight 0.04 kg

Product Description

CP 40KVA/40KW Rack UPS Specifications: Phase: Three Phase Form Factor: Rackmount, Tower UPS Topology: Online Double Conversion Energy Saving Technology: Online ECO Mode Efficiency > 98.9% Normal Mode Efficiency ( % ): 95.8% Battery Mode Efficiency ( % ): 95.5% Active PFC Compatibility: Yes Parallel Expansion (Max. Units): 4 Dual Power Inputs: Yes Generator Compatibility: Yes Nominal Input Voltage ( Vac ): Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac Input Voltage Range ( Vac ): Line to Neutral (L-N): 132 ~ 276 Vac, Line to Line (L-L): 228 ~ 478 Vac Input Frequency Range ( Hz ): 40 ~ 70 Rated Input Current ( A ): 64.5 Input Power Factor: 0.99 Overload Protection (Bypass): 125% Load for continuous operation, 150% Load for 10 min, 1000% Load for 5 ms Input Connector Type: Hardwire Terminal Block Capacity (VA): 40000 Capacity (Watts): 40000 On Battery Waveform: Pure Sine Wave Output Voltage Setting: Configurable Output Frequency Setting: Configurable Rated Output Voltage ( Vac ): Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac Output Voltage Tolerance ( % ): Balance Load: 1 % Output Frequency ( Hz ± % ): 50 ± 0.2, 60 ± 0.166 Power Factor: 1 ECO Mode Voltage Tolerance: ± 5 % Overload Protection: Internal Current Limiting, Fuse Overload Protection (Line Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms Overload Protection (Battery Mode): 102~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load for 200 ms Crest Factor: 3 : 1 Harmonic Distortion (Linear Load): THD 1% Harmonic Distortion (Non-linear Load): THD 3% Internal Bypass: Automatic Bypass Synchronization Window (Nominal) ( Hz ): ± 4 Outlet Type: Hardwire Terminal Block x 1 Typical Transfer Time ( ms ): 0 Maximum Charging Current ( A ): 12 Typical Charging Current ( A ): 3.6 Compatible Battery Types: VRLA Recharge Power Setting: Configurable Charger Voltage Tolerance ( % ): 1 % Start On Battery: Yes Smart Battery Management (SBM): Yes Compatible Extended Battery Module (EBM): BME480V55ART5U External Battery Quantity: 12V x 40pcs EMI/RFI Filtration: Yes LCD Panel: Yes LCD Types: Color LCD, LCD Touch Panel LCD Orientation: Rotatable LCD Manual LCD Information Display: Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log LCD Setting & Control: Mode Setting, Input & Output, Battery Setting, Communication, Event & Log, Security Setting, Language LED Indicators: Yes Shortcut Button: Alarm On/Off Serial Port: RS232 x 1 + RS485 x 1 + Dry Contact x1 Dry Contact (with Relay): Yes Emergency Power Off (EPO) Port: Yes Audible Alarms: Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery Power Management Software: PowerPanel Business (Recommended) SNMP/HTTP Remote Monitoring: Yes - with optional RMCARD205 Compatible with Racks (3 Phase): Yes Enclosure Construction: Metal Color: Black Ingress Protection: IP20 Rackmount Rail: Yes Dimensions (mm.): 433 x 219 x 730 Weight (kg.): 42.8 Installed Rack Height ( U ): 5 Operating Temperature (°C): 0 ~ 40 Operating Relative Humidity (Non-condensing) ( % ): 0 ~ 95 Operating Elevation (meters): 0-3,000 Storage Temperature (°C): -40 ~ 70 Storage Relative Humidity (Non-condensing) ( % ): 0 ~ 95 Audible Noise at 1.0M from Surface of Unit: 66dBA(100% load), 56dBA(50% load) Features: Three-phase Design High Output Power Factor Color LCD Panel Dual Inputs Pure Sine Wave Output Battery Cold Start SNMP/HTTP Remote Management Capability (Optional) Extended Battery Module (EBM) Online (Double Conversion) UPS Topology Rack Modular Design LCD Touch Panel Generator Compatible UPS Parallel Expansion Smart Battery Management (SBM) PowerPanel Management Software